· MVDC – 220
Direct operated, Body width: 22mm, Port size: 1/8, Operating pressure range: 0.01~0.7 MPa.
· MVDC – 300
Port size: Rc1/8, Rc1/4, 3 port 2 position, Medium: Air, low vacuum, Operating perssure range: -101 kPa ~ 1 MPa.
· MVDY – 100
Direct operated, Body width: 10 mm, No. of port: 3, Operating pressure range : 0~0.7 MPa, Effective orifice: 0.09~0.28 mm2, Flow : 5~15 l/min.
· MVB – 100
25-Pin D-sub connector, Simple electric wire system, Max. operating frequency: 5Hz.
· MVB – 156
25 Pin D-sub connector. Simple electric wire system. Max. operating frequency: 5Hz.
· MVB – 220/300/460
DC 24V. 25 Pin D-sub connector (cable length 3m). Simple electric wire system.
· MVB1 – 100
26-Pin flat connector. Simple electric wire system. Max. operating frequency: 5Hz.
· MVJA – 156
All-in-one gasket for the base can be easier to increase the number of valve blocks. Plug-in design reduces the time for wiring and labor cost.
· MVE – 100
With MVSY-100 solenoid valve, wiring time can be reduced, Labor cost can be reduced, High flexibility for system expansion, Circuit protection and self diagnosis function, Reduce error of wiring, Web server function.
· MVE – 156
With MVSY-156 / MVSP-156 solenoid valve, wiring time can be reduced, Labor cost can be reduced, High flexibility for system expansion, Circuit protection and self diagnosis function, Reduce error of wiring, Web server function.
· MVE2
Solenoid valve: MVSY-100, 156, 188, MVSC1-220, Quick tube fittings can be installed, Fast troubleshooting thanks to multi-angle LED display, It is easy to repair due to solenoid valves can be replaced simple and fast.
· MPVH
piston direct acting high-flow proportional valve, High-flow pressure compensated proportional valve designed primarily for mixing and dosing of gases in ventilation, respiratory equipment,anesthesia, and analytical instruments. Product life: 100 million.
· MVPM
piston direct acting precision flow proportional valve, Direct acting orifice size from ø0.2 to 2 mm. Pressure up to 12 bar. Suited for dosing precisely gases in the medical and in the analytical field.
· MVAA – 100
Port size: M5×0.8,Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.
· MVAA – 180
Port size: 1/8, Operating pressure range:0~0.8 MPa, Proof pressure: 1 MPa.
· MVAA – 220
Port size: 1/4, Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.
· MVAA – 260
Port size: 1/4, Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.
· MVAA – 300
Port size: 3/8, Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.
· MVAA – 460
Port size: 1/2, Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.
· MVMA – 260
Port size: 1/4, Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.
· MVMA – 300
Port size: 3/8, Operating pressure range: 0~0.8 MPa, Proof pressure: 1 MPa.