Super Precision Air Regulators RS・RR Series
- Pneumatic Products
- Fujikura Composites
- Super Precision Air Regulators RS・RR Series
Download PDF (1.177,6 Kb)
・Servo-balanced system comprising BF Rolling Diaphragm and Measuring capsule
provides exceptionally precise and stable pressure control with constant
bleed feature.
RR series offer exceptionally precise 1:1 pressure relay control with ±
bias adjustment capability by external pilot operation.
Combined with a stepping Motor , RS・M/S series offers absolutely
precise pressure Control by External Electric pulse Signals.
Model RS・HR and Model RR・HR have as twice as large relief flow capacity
compared with that of respective basic model.
・High Precision Pressure Control sensitivity ≦0.1 % F.S. , Repeatability
≦±0.1 % F.S.
・Extremely Excellent Relief-, Pressure-, and Flow- Characteristics Particularly
theoretical Relief Sensitivity is as low as 0.03 KPa.
・Excellent Start-up Stability, No readjustment of regulated pressure required
even after long interval.
・Remote Control of Pressure (RR Series) Capable of simultaneous remote
control of
different pressures.
Specifications |
Internal Pilot System |
RS-4 |
RS-8 |
RS・HR-8 |
External Pilot System |
- |
RR-8 |
RR・HR-8 |
Working Fluid |
Clean Compressed Air |
Range Set Pressure MPa |
0.014 ~ 0.42 |
0.014 ~ 0.84 |
Supply Pressure MPa(※1) |
1.MAX. |
Input Pilot Pressure Range MPa |
- |
0.14 ~ 0.84 |
Relief Device |
Equipped |
Repeatability %.F.S |
≦ ± 0.1 |
Accuracy %.F.S |
≦ 0.1 |
Minimum Relief Pressure kPa |
0.03 ( Theoretical value ) |
Relief Flow Nl/min(※2) |
130 |
260 |
Air Consumption Nl/min(※3) |
≦ 3.7 |
Working Temperature Pipe Port ℃ |
5 ~ 60 |
Pipe Port Rc(PT) |
1/8 ・ 1/4 ・ 3/8 |
Pressure Gauge Port Rc(PT) |
1/4( Two ports ) |
Mounting |
Bracket (Standard) |
※1:For Model RR |
※2:At Set pressure 0.2MPa |
※3:Features constant bleed air discharged into atmosphere |
Ordering Information |
RS |
・ |
HR |
- |
8 |
- |
2 |
- |
BA |
- |
G025 |
① |
|
② |
|
③ |
|
④ |
|
⑤ |
|
⑥ |
① |
② |
③ |
④ |
Model |
Relief Flow |
Set Pressure Range |
Pipe Port Size |
RS |
Internal Pilot |
None |
Standard |
4 |
0.14~0.42MPa |
1 |
Rc(PT)1/8 |
RR |
External Pilot |
HR |
High Relief |
8 |
0.14~0.82MPa |
2 |
Rc(PT)1/4 |
|
|
|
|
3 |
Rc(PT)3/8 |
⑤ |
⑥ |
Bias knob※ |
Pressure Gauge |
None |
- |
None |
- |
B A |
Equipped |
G025 |
0~0.25MPa |
|
|
G060 |
0~ 0.6MPa |
|
|
G100 |
0~ 1 MPa |
|
※Adapted RR Series